@import((rwml-menu))
AccueilHome
- Notre entreprise- Our enterprise
- Nouvelles- Latest News
- Emplois- Employment
Produits et ServicesProducts & Services
Extincteurs portatifs Portable Extinguishers
- Inspections- Inspections
- Remplissage- Refilling
- Essai hydrostatique- Hydrostatic testing
- Classes d’incendie- Classes of fire
- Utilisation de base- Basic use
- Codes et Règlements- Codes & Reglementation
Boyaux d'incendie Fire hoses
- Inspection / Maintenance- Maintenance / Inspection
- Boyaux Cabinet Incendie- Cabinet fire hose
- Boyaux Industriels- Industrial hoses
- Accessoires- Accessories
Éclairage d’urgenceEmergency lighting
Systèmes fixesFixed systems
- Hotte de cuisine- Kitchen hood
- Salle informatique- Computer room
- Risques industriels- Industrial risks
GicleursSprinklers
Bornes incendieFire terminals
Pompes incendieFire pumps
Alarme incendieFire alarm
Mesures d’urgenceEmergency measures
- Plans d'évacuation- Evacuation plans
- Plans Mesures d'urgence- Emergency action plans
- Photoluminescence- Photoluminescence
FormationTraining
CataloguesCatalogs
Fiches MSDSMSDS
ContactsContact us
AdminAdmin

INSPECTION ET MAINTENANCE

Les normes ont changé et il n'y a presque plus de boyau incendie qui s'installe dans les nouveaux édifies. Certains établissements peuvent même obtenir des dérogations de la part des autorités compétentes ayant juridiction pour l'enlèvement des boyaux existants. Mais si les boyaux sont existants dans un bâtiment, il doivent obligatoirement être maintenus et entretenus en vertu des normes applicables.

La maintenance des boyaux d'incendie découle du Code National de Prévention des Incendies (CNPI), la section 6.4 nous réfère à la norme #25 de la National Fire Protection Association (NFPA # 25). la vérification doit se faire annuellement. Les boyaux n’ont pas à être apportés en atelier à chaque année, seulement si les circonstances durant l'inspection l'exige ou un essai hydrostatique est requis.

Le boyau de cabinet incendie doit subir un essai hydrostatique 5 ans après sa date de fabrication, par la suite la fréquence des essais hydrostatiques est de 3 ans.

INSPECTION AND MAINTENANCE

Standards have changed and there is hardly any fire hose that is installed in the new built. Some institutions can even obtain waivers of the competent authorities having jurisdiction for the removal of existing casings. But if the hoses are in an existing building, it must necessarily be kept and maintained in accordance with applicable standards.

Maintenance of fire hoses stems from the National Fire Prevention Code (NFC), we refer section 6.4 Standard # 25 of the National Fire Protection Association (NFPA # 25). verification must be done annually. Hoses do not have to be made in the workshop each year, only if circumstances during the inspection required or a hydrostatic test is required.

The fire hose cabinet must undergo a hydrostatic test 5 years after the date of manufacture, subsequently frequency hydrostatic testing is 3 years.
Contacts et Ressources
Contacts and Resources

CONTACT US

AL CARRIÈRE EXTINCTEUR
4850 rue Louis-B.-Mayer
Laval, QC
H7P 0H7

Telephones
LAVAL
450-687-9000

MONTREAL
514-337-8888

TOLL FREE
1-877-462-3634
(1-877-INCENDIE)

E-mail
info@alcarriere.com

Contacts

AL CARRIÈRE EXTINCTEUR
4850 rue Louis-B.-Mayer
Laval, QC., H7P 0H7

Telephones
LAVAL : 450-687-9000
MONTREAL : 514-337-8888

TOLL FREE
1-877-462-3634
(1-877-INCENDIE)


E-mail
info@alcarriere.com

NUMÉROS UTILES

AL CARRIÈRE EXTINCTEUR
4850 rue Louis-B.-Mayer
Laval, QC
H7P 0H7

Téléphones
LAVAL
450-687-9000

MONTRÉAL
514-337-8888

SANS FRAIS
1-877-462-3634
(1-877-INCENDIE)

Courriel
info@alcarriere.com

R.B.Q.: 2853-2539-87

Contacts

AL CARRIÈRE EXTINCTEUR
4850 rue Louis-B.-Mayer
Laval, QC
H7P 0H7

Téléphones
LAVAL : 450-687-9000
MONTRÉAL : 514-337-8888

SANS FRAIS
1-877-462-3634
(1-877-INCENDIE)


Courriel
info@alcarriere.com